Introduction
Local gas distribution companies utilize PTZ gas volume correctors to convert gas volume from operating conditions to reference pressure and temperature conditions. They are a key element in the gas value chain— from the meter to billing data. Honeywell’s EC 350 PTZ Gas Volume Correctors are intended to simplify and optimize custody transfer and industrial measurement. This new electronic corrector platform offers best-in-class accuracy, expanded memory, advanced diagnostics and integrated cellular communications. The EC 350 also reduces maintenance requirements and is intuitive and simple to use.
Features & Benefits
- Meter-, rotary- or wall-mount
- Direct mounting to the Elster® Rotary Gas Meter RABO®
- 1 or 2 pressures, new digital Plug and Play Pressure Transducer
- Corrected volume calculation according to AGA-7, AGA-8 gross method 1 & 2, AGA8 Detailed and NX-19
- Fully mappable and configurable audit trail memory, including options for multiple audit trail logs (up to 5 different independent logs)
- Multi-line dynamic contrast(LCD display)
- Outputs: 4 opto-couplers(3 pulse + 1 alarm)
- AMR-ready and compatible with Itron, Sensus, Aclara and other AMR devices
- RS232/485 communication port
- Optional cellular radio or landline modem
- Optional 4-20 mA (requires external loop power), additional RS232/485, Mux DI/ DO board
- IrDA configuration connection
- Honeywell MasterLink programming software
- Call-In over IP network to major billing systems using Invisiconnect software.
Datasheet
Applications
♦ Custody transfer Gas Metering Skids
♦ Gas Distribution & Explorations